The S&L Catalog
Line Interactive, Voltage Regulating - 1000 VA/700 W UPS
Model: SRA 10000
- Emergency Power Off (EPO) - immediately remove power from UPS outlets in case of an emergency.
- Hot Swappable Battery Design - ensures uninterrupted performance during battery replacement.
- Rack, Tower or Wall Installation - installation options for a variety of power continuity applications.
- Easy to View LCD Panel - displays UPS and electric power status. Rotating design can orient the front panel display to suit rack, tower or wall installation. Vaules available on display include: load level, voltage and frequency, UPS status, battery charg
- Maintenance Free Batteries - last 3 - 5 years under normal operations and conditions. Replacement batteries are available.
The SRA Series of battery backup UPS models feature value priced yet feature rich UPS technology incorporating automatic voltage regulation (line interactive) function that preserves battery power and supports sensitive electronic equipment during brown outs. Once incoming voltage drops below operational levels, SRA switches to battery to maintain power continuity. These products also provide 960 Joules of power line surge protection.
Voltage Regulation - provides support during low voltage sags. When utility power ranges between 90 and 150 VAC, voltage output stabilizes between 103 and 136 VAC.
Line Interactive circuitry monitors the incoming voltage level and routes current through the appropriate taps on a buck/boost transformer to raise or lower output voltage, improving the performance of powered equipment and extending the usable range of the utility power before switching to battery mode.
- Emergency Power Off (EPO) - immediately remove power from UPS outlets in case of an emergency.
- Hot Swappable Battery Design - ensures uninterrupted performance during battery replacement.
- Rack, Tower or Wall Installation - installation options for a variety of power continuity applications.
- Easy to View LCD Panel - displays UPS and electric power status. Rotating design can orient the front panel display to suit rack, tower or wall installation. Vaules available on display include: load level, voltage and frequency, UPS status, battery charg
- Maintenance Free Batteries - last 3 - 5 years under normal operations and conditions. Replacement batteries are available.
- Rackmountable - Yes
- Spec Sheet available - Yes
- Frequency Range: 60 Hz +/- 0.8%
- Height: 3.40 in
- Storage Temperature: -13 F to 104 F
- Transfer Time: AC to DC 6 - 10 ms (Typical)
- Width: 18.90 in
- Shipping Weight: 37.50 lbs
- AC Voltage: 120 Volts
- Audible Noise: Output at 3 ft < 45 dBA
- Power Cord: 10 ft, NEMA 5-15P (NEMA 5-20P for SRA 20000)
- Humidity: 20 to 90% RH (non-condensing)
- Surge Energy Rating: 960 Joules
- Battery Type: Sealed, Non-Spillable, Valve Regulated, Maintenance Free, Lead Acid
- Low Voltage: Transfer To Battery 89 VAC
- Receptacles: 8 x NEMA 5-15R
- Product Weight: 31.30 lbs
- Active Power: 525 Watt
- Number of Outlets: 3
- Estimated Runtime: 0.23 hours
- Estimated Runtime: 14 minutes
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- Cord Length (in/mm): 120 in
- EMI/RFI Noise Filtration: >45dB Normal and Common Mode
- AC Voltage (Minimum): 90 Volts
- AC Voltage (Maximum): 150 Volts
- Overload capacity: 110% 20 - 60 Seconds, 150% Immediate Shutdown
- Length: 16.10 in
- Status Indications: Battery Capacity, Load Percentage, Input Power Source, External Power Line, Fault Indications
- Control Select Buttons: On/Off/Test, Alarm Silence, Display Control (Scroll)
- Warning Indicators: Low or Bad Battery, Current Overload, Site Wiring Fault, Over Temperature, UPS Failure
- Surge Capacity: 6,500 Amps Total (One Time)
- Output Voltage - Line Interactive Mode: 103 - 136 VAC
- Output Voltage - Battery Mode: 120 VAC +/- 5%
- Harmonic Distortion (THDU): 30.3 % to 37.2 % = Total, 14.5 % to 18.7 % = Single
- Topology (Design): Line Interactive - Simulated Sine Wave
- Load Shedding (Outlet Control) Requires third-party software: 2 Banks of 3 Outlets and 2 Unswitched. SRA 20000 has 1 Unswitched L5-20R
- Return To Utility Power: 94 VAC
- High Voltage: Transfer To Battery 151 VAC
- Typical Recharge: Time 8 Hours to 90% from Full Discharge
- Typical Service Life: 3 to 5 Years With Proper Operation
S&L Integrated
7 Midway Road
Thomasville, GA 31757
USA
(229) 378-8866
https://slintegrated.com/