The S&L Catalog
Green Light Dimmer Expansion Module with DALI Communication
Series: GL-EXP
Model: GL-EXP-DIM-DALI
Part #: 6507035
- Single-channel lighting dimmer
- DALI® system interface
- Supports dimmable LED, incandescent, magnetic low-voltage, neon/cold cathode, and 2-wire fluorescent lighting loads
- Rated 16 Amps at 100-277 Volts AC
- Forward phase dimming
The Crestron Green Light® GL-EXP Series delivers a family of professional lighting control modules for Cresnet® or DALI® based lighting systems. Designed for easy installation on a wall or above a suspended ceiling, these modules offer a perfect solution for adding extra lighting zones to any system without requiring an additional lighting cabinet.
The GL-EXP-DIM-DALI is a single-channel dimmer expansion module designed to control LED, incandescent, magnetic low-voltage, neon/cold cathode, or 2-wire dimmable fluorescent lighting loads. Utilizing proprietary zero-cross filter technology, the GL-EXP-DIM-DALI compensates for line voltage and frequency fluctuations, providing superior immunity to power line noise and a dramatic reduction in lamp flicker.
Forward Phase Dimming
The GL-EXP-DIM-DALI employs forward phase (leading edge) dimming to handle inductive load types like magnetic low-voltage and neon, as well as incandescent, LED, and 2-wire fluorescent.
DALI® Communications
The GL-EXP-DIM-DALI communicates using the DALI (Digital Addressable Lighting Interface) standard, which enables interoperability with other DALI compliant lighting control products from Crestron and other manufacturers. Interfacing a network of DALI dimmers and other devices with a Crestron lighting control system is facilitated using the DIN-DALI-2 (sold separately).
Emergency Lighting Control
The GL-EXP-DIM-DALI is UL® 924 listed for use in controlling an emergency lighting load. In the event of a power failure indicated by a loss of DALI network communication (system failure), the GL-EXP-DIM-DALI turns on the lighting load if it is off (assuming line power is supplied by a backup power source). The system failure dimming level can be preset to any value when commissioning the lighting system, so even if the load is already on prior to a power failure, it will change to the preset level when a system failure is detected.
Plenum Rated NEMA Enclosure
The GL-EXP-DIM-DALI is designed to be mounted to a vertical surface and is UL 2043 compliant to allow for installation in an environmental air-handling space above a suspended ceiling. Conduit knockouts are provided on the bottom and lower sides of the unit. All connections are made via screw terminals behind the front cover.
- Single-channel lighting dimmer
- DALI® system interface
- Supports dimmable LED, incandescent, magnetic low-voltage, neon/cold cathode, and 2-wire fluorescent lighting loads
- Rated 16 Amps at 100-277 Volts AC
- Forward phase dimming
- Zero-cross filter technology for reduced lamp flicker
- Extreme stability under noisy power line conditions
- Built-in air gap relay
- UL® 924 listed for emergency lighting control
- Surface mountable NEMA Type 1 enclosure
- Mounts on a wall panel or above a suspended ceiling
- UL 2043 listed for installation in an environmental air handling space
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- Depth: 3.16 in
- Height: 8.78 in
- Width: 6.39 in
- Product Weight: 3.43 lbs
- Certifications: FCC, CE
- AC Voltage (Maximum): 277 Volts
- AC Voltage (Minimum): 100 Volts
- Current Draw: 16 Amps
- Load Control:
•Dimmer Channels: 1
•Dimmable Load Types: LED, incandescent, neon/cold cathode, magnetic low-voltage, 2-wire dimmable fluorescent - Connections:
•NEUT: (3) Captive screw terminals, Neutral connections for feed and load
•24 to 10 AWG (0.25 to 4.0 mm2) wire size
•LINE: (2) Captive screw terminals, Line power input and pass-through
•24 to 10 AWG (0.25 to 4.0 mm2) wire size
•DIM: (1) Captive screw terminal, Dimmed load output
•24 to 10 AWG (0.25 to 4.0 mm2) wire size
•N/C: (1) Captive screw terminal, No connection (not used)
•OVERRIDE: (2) Captive screw terminals
•Low-voltage contact closure sensing input
•Activates override mode when a closure is sensed
•26 to 14 AWG (0.14 to 1.5 mm2) wire size for use with Class 2 wiring only
•CRESNET: (4) Captive screw terminals
•Cresnet slave port (communications only, does not use Cresnet power)
•26 to 14 AWG (0.14 to 1.5 mm2) wire size for use with Class 2 wiring only
•Ground: (1) 3-terminal grounding block - Controls and Indicators:
•PWR: (1) Green LED, indicates line power is applied to either LINE terminal
•NET: (1) Yellow LED, indicates Cresnet network communication
•ERR: (1) Red LED, indicates a variety of error conditions via blinking patterns (refer to the installation guide)
•ON/OFF: (1) Pushbutton and (1) red LED, pushbutton toggles the load output on and off (press and hold to cycle the dimming level up and down), LED indicates the load output is energized
•RESET: (1) Pushbutton, initiates hardware reset
•SW1: (1) Two-position slide switch (behind front cover), enables/disables the zero-cross detection filter (disabled by default)
•SW2 - SW4: (3) Two-position slide switches (behind front cover), not used - Construction:
•Enclosure: NEMA Type 1, galvanized steel with gray matte powder coated removable front cover panel, extruded aluminum heat sink on rear, (2) integral mounting flanges, (4) 1/2 or 3/4-inch conduit knockouts on bottom and lower left and right sides
•Mounting: Surface mount, must be oriented upright and mounted to a vertical surface with 6 inches (153 mm) minimum spacing above and below for proper ventilation and heat dissipation
S&L Integrated
7 Midway Road
Thomasville, GA 31757
USA
(229) 378-8866
https://slintegrated.com/